sync:data_extraction [2021/06/02 03:42] – [Extracting Information] Scott Cunliffesync:data_extraction [2025/01/21 22:07] (current) – external edit 127.0.0.1
Line 7: Line 7:
 The source file information extract will vary depending on your backup software. The source file information extract will vary depending on your backup software.
  
-==== Data Extraction From Networker ====+==== Data Extraction From BackupExec ====
  
-Using the administrative tool mminfo, the Volume data needs to be extracted from the Networker save sets and exported into CSV file format. 
  
-To get a report that is suitable for the TapeTrack Sync command, the following minimum arguments should be used: +The CSV report in BackupExec is created by running PowerShell script and output to CSV file.
-<sxh> +
-mminfo -xc, --r "volume,barcode,family,type,location,pool" > report.csv +
-</sxh> +
-==== Data Extraction From TSM ====+
  
-Using the Tivoli Storage Manager administrative tool dsmadmc, the Volume data needs to be extracted from both the DRM and Volume tables and exported into csv file format.+Further details on the conversion process can be viewed at [[cookbook:backupexec|Backup Exec Cookbook]]
  
-To get a report that is suitable for the TapeTrack Sync command, the following minimum arguments should be used:+==== Data Extraction From Commvault ====
  
-=== From the DRM table: ===+The Storage Information Report is created via the Commvault GUI and output to CSV format, accessible from the reports tab.
  
-From the DRM table, select the fields: +Further details on the conversion process can be viewed at [[cookbook:commvault|Commvault cookbook]]
-  * volume_name: Used to determine the [[object:volume|Volume-ID]] in TapeTrack. +
-  * state: Used to determine the location the [[object:volume|Volume]] should be+
-  * stgpool_name: Used to set the [[object:volume|Volume]] [[object:volume|Description]].+
  
-<sxh> +==== Data Extraction From Data Protector ====
-dsmadmc -dataonly=yes -id=userid -pa=password -tcpserveraddress=tsm01.gazillabyte.local \ +
-        -displaymode=table -outfile=TSM-DRM.csv -commadelimited "select volume_name,state,stgpool_name from drmedia" +
-</sxh>+
  
-=== From the Volume table: ===+The onmirpt command is available on systems with the Data Protector User Interface component installed
  
-From the [[object:volume|Volume]] tableselect the fields: +Use the omnirpt command to extract data to a text file using: 
-  * volume_name: Used to determine the [[object:volume|Volume-ID]] in TapeTrack + 
-  * location: Used to determine the location the [[object:volume|Volume]] is+Output from omnirptwhile tab delimitered, can produce offset columns depending on string lengths. To ensure the column offsets are consistent the output is passed through TMSS10CSV2Fixed producing a fixed length text file.  
-  * stgpool_name: Used to set the [[object:volume|Volume]] [[object:volume|Description]]. + 
-<sxh> +Further details on the conversion process can be viewed at [[cookbook:dataprotector|Data Protector Cookbook]] 
-dsmadmc -dataonly=yes -id=userid -pa=password -tcpserveraddress=tsm01.gazillabyte.local \ + 
-        -displaymode=table -outfile=TSM-VOL.csv -commadelimited "select volume_name,location,stgpool_name from volumes" +==== Data Extraction From Netbackup Vault ==== 
-</sxh>+ 
 +Using the administrative tool vmquery, the Volume data can be extracted into a text file
 + 
 +The text file is then converted to a CSV file to properly format the data, along with the dates, to allow correct loading into the Sync, using the command line program TMSS10SingleSpace. 
 + 
 +Full definition and implementation example for extraction of data and synchronization with Netbackup is at [[cookbook:netbackup|NetBackup Sync Cookbook]] 
 +==== Data Extraction From Networker ==== 
 + 
 +Using the administrative tool mminfo, the Volume data needs to be extracted from the Networker save sets and exported into CSV file format. 
 + 
 +Full definition and implementation example for extraction of data and synchronization with Networker is at [[cookbook:networker|NetWorker Sync Cookbook]] 
 +==== Data Extraction From TSM ==== 
 + 
 +Using the Tivoli Storage Manager administrative tool dsmadmcthe Volume data needs to be extracted from both the DRM and Volume tables and exported into csv file format. 
 + 
 +Full definition and implementation example for extraction of data and synchronization with TSM is at [[cookbook:tsm|Tivoli Storage Manager Sync Cookbook]].
  
 ==== Data Extraction For VEEAM ==== ==== Data Extraction For VEEAM ====
Line 48: Line 52:
 VEEAM differs from other backup software in that a direct ODBC connection is made using the definition file rather than extracting the data to file and then using a definition file to read it. VEEAM differs from other backup software in that a direct ODBC connection is made using the definition file rather than extracting the data to file and then using a definition file to read it.
  
-Sample code placed at the beginning of the definition to connect to sample database veeam2. +Full definition and implementation example for extraction of data and synchronization with VEEAM is at [[cookbook:veeam|VEEAM Sync Cookbook]].
- +
-<sxh> +
-# Connect to Veeam database +
-SetODBC("DSN=veeam2"); +
-# Extract data +
-SetSQL("SELECT [barcode],[media_pool_id],[last_write_time] FROM [VeeamBackup].[dbo].[Tape.tape_mediums]"); +
-</sxh>+
  
-<- sync:fields| Sync Fields ^ sync:introduction|introduction ^  ->+<- sync:sources|Sync Sources ^ sync:introduction|introduction ^ sync:fields| Sync Fields ->
sync/data_extraction.1622605359.txt.gz · Last modified: 2025/01/21 22:07 (external edit)